Fridge temp range se bahar chala gaya (excursion) — LA/emergency dawai kharab to nahi?

Us fridge ke temperature-sensitive drugs quarantine karo, manufacturer/pharmacist se stability check karo, breach ko incident + register me log karo, aur repair/backup ke baad hi wapas use karo.

Where in ORALZY: NABH Hub → Daily Logs → Registers + Incidents (CAPA)

Diagnosis: Temperature excursion (e.g. LA cartridges, emergency adrenaline, kuch vaccines) potency gira sakta hai. Range NABH me define honi chahiye.

Karo:

  1. Turant us fridge ke temp-sensitive stock ko 'Do Not Use' tag ke saath quarantine karo.
  2. Kitni der aur kitna temperature bahar gaya note karo (min/max thermometer se). Manufacturer stability data / pharmacist se poocho ki drug usable hai ya discard.
  3. NABH Hub → Incidents me ek incident banao aur temperature log/register me excursion entry karo. Discard hua stock stock-register me out karo.
  4. CAPA: root cause (power cut/fridge fault/door open), corrective (repair + backup arrangement), preventive (temp alarm + daily log + power backup).

Aage se: Fridge me min-max thermometer + alarm, aur daily temperature log schedule. Emergency drug list (NABH Hub → Master Lists → Drug Lists) ke stock ko protect karo.

Edge case: Emergency drugs (adrenaline) agar affected — replace pehle karo, kyunki anaphylaxis ke liye active drug hona critical hai.

Quick steps

  1. Affected temp-sensitive drugs turant quarantine karo
  2. Excursion duration + temperature note karo (min-max)
  3. Manufacturer/pharmacist se usable ya discard confirm karo
  4. Incident + register me excursion log karo, discard stock out karo
  5. CAPA me repair/backup/alarm preventive daalo

temperatureexcursioncold-chaindrugsquarantineincidentcapaemergency-drugsstability