Aisa tab hota hai jab RVG software me purane patient ki file khuli reh gayi thi ya bridge ne naam se galat match kar liya.
FIX
- Galat patient ki Imaging gallery me woh X-ray kholo (lightbox).
- Use sahi patient ko assign karo — assign karne par matchStatus 'confirmed' ho jata hai.
- IMPORTANT: manual re-assign se system RVG-software-ID → ORALZY-patient ki mapping bhi seekh leta hai (manual confirmation purani auto-mapping ko override karti hai) — matlab agli baar us device-ID se aaya X-ray seedha SAHI patient me girega. Galti khud repair ho jati hai.
Agar image bilkul hi bekar hai (test shot) to lightbox me Delete bhi hai — par dhyan raho, imaging delete permanent hai, ye Recycle Bin wala system nahi hai.
AAGE SE
X-ray lene se pehle RVG software me sahi patient select karo; galat auto-match dikhe to turant re-assign karo taaki mapping sahi seekhe. Seekhi hui mappings Settings → Imaging Bridge me dikh bhi jati hain aur galat ho to wahan se delete kar sakte ho.